Electrical · Enclosure ratings

NEMA to IP rating crosswalk.

Enter a NEMA enclosure type and get the approximate IP code, with the reasons the match is never exact.

Short answer: NEMA 4 and 4X map to about IP66, NEMA 6 to IP67, NEMA 6P to IP68 and NEMA 12 to IP52. These are approximations in one direction only, and NEMA 4X adds corrosion resistance that IP does not test.

Pairings stated the same way by two separate manufacturer and distributor pagesRetrieved 20 October 2026

Advertisement
Types 4, 4X, 6, 6P or 12. Nothing leaves this page.

Result

Enter a NEMA type such as 4X and press Find IP match.

Advertisement

What this crosswalk is, and is not

NEMA enclosure types come from the North American NEMA 250 standard. IP codes come from IEC 60529. They are written by different bodies, tested differently and aimed at different problems, so there is no official conversion between them. What exists is a set of rule-of-thumb mappings that enclosure makers and distributors publish. This page lists only the pairings that two separate pages state the same way, and it says so when a pairing is shaky.

The direction matters. Going from a NEMA type to an approximate IP code is a reasonable minimum reference for dust and water. Going the other way is not safe: an IP66 enclosure is not automatically NEMA 4X, because IP66 says nothing about corrosion.

The crosswalk

NEMA typeApproximate IPWhat to know
4IP66Described as watertight and not corrosion tested. One distributor writes the match as IP65 or IP66, so treat IP66 as the figure to confirm.
4XIP66The same ingress mapping as type 4. The X adds corrosion resistance, which IP does not test at all, so the IP code understates the NEMA type.
6IP67Temporary submersion. One distributor writes IP67 or IP68.
6PIP68IP68 depth and duration are whatever the maker states, so check the datasheet.
12IP52IP52 is dust-protected with drip protection at a 15 degree tilt (digits 5 and 2). Far weaker on water than types 4 to 6P.

Other NEMA types such as 1, 2, 3, 3R, 3S, 5 and 13 are not in this table. One equivalence chart lists IP numbers for them, but we found only that one page for those types, and we do not publish a pairing we cannot confirm twice.

Why 4X versus IP66 is the classic trap

People often write 4X and IP66 as if they were the same. The ingress numbers do line up: both cover dust and powerful water jets. The difference is the X. NEMA 4X adds corrosion resistance, and the IP system has no corrosion class at all. An IP66-rated plastic box and a NEMA 4X stainless box may both survive a hose, yet only one was tested for corrosion. One distributor’s comparison puts the rule bluntly: when a specification requires corrosion protection, do not substitute IP66 for NEMA 4X without verifying the enclosure material. The same page calls the pairing approximate and notes it is general information, not engineering advice.

The test methods differ as well. IP66 is verified under IEC 60529 and NEMA 4X under NEMA 250, so a certificate for one is not a certificate for the other. A dual-marked NEMA 4X/IP66 product helps only if the manufacturer supplies evidence for that specific model.

What NEMA covers that IP does not

The IP system describes ingress of solids and water. NEMA enclosure types also deal with factors IP does not address: corrosion, icing, oil and coolants, and, in some types, hazardous atmospheres. That is why Index Enclosures warns against assuming an IP-rated enclosure meets the full NEMA requirement just because the ingress numbers match, and why APG’s chart says its conversions are estimates to be used as a guide. A crosswalk answers one narrow question: roughly how much dust and water does this NEMA type keep out?

Worked example

Hypothetical case one: a spec for an outdoor controller reads NEMA 4X and the catalogue offers an enclosure marked only IP66. The tool returns IP66 for 4X, so the ingress level looks right, but the page tells you the corrosion requirement is unanswered. Ask for the material and a NEMA 4X marking. Hypothetical case two: a European data sheet calls for IP67 and you find a NEMA 6 enclosure. NEMA 6 maps to IP67, so it is a plausible match for the submersion requirement, though you still want the maker’s statement of depth and time. Hypothetical case three: a spec says IP54 and you hold a NEMA 12 enclosure. NEMA 12 maps to IP52, which is lower on water than IP54, so it does not clearly meet that requirement.

Common mistakes

Who this is for

Installers, panel shops and buyers who hold a specification in one system and a product in the other, and want a fast sanity check before asking the supplier for paperwork. The companion IP rating chart explains each digit of the IP side.

What this does not cover

Advertisement

Frequently asked questions

Is NEMA 4X the same as IP66?

No. They map to the same dust and water level, but NEMA 4X adds corrosion resistance and the IP system has no corrosion class. The two are tested under different standards.

Is an IP66 enclosure NEMA 4X?

Not automatically. IP66 does not prove corrosion resistance, so check the enclosure material and ask for NEMA 4X documentation for that model.

What is NEMA 6P in IP?

NEMA 6P is mapped to IP68 by both charts we compared. IP68 conditions are set by the manufacturer, so read the stated depth and duration.

What is NEMA 6 in IP?

NEMA 6 is mapped to IP67 by the charts we compared, which is the 30-minute immersion level. One distributor writes IP67 or IP68.

What is the IP equivalent of NEMA 12?

About IP52, which is dust-protected with drip protection at a 15 degree tilt. Its water protection is far lower than types 4 to 6P.

Can I convert an IP rating to a NEMA type?

Not safely. Sources describe NEMA to IP as a rough minimum reference only, because NEMA adds corrosion, icing and oil requirements that IP never tests.

Why is NEMA type 3R not in this table?

We publish only pairings that two separate pages state the same way. We found one page that maps type 3R, so we left it out rather than guess.

Which standard defines NEMA enclosure types?

NEMA 250. IP codes are defined in IEC 60529. We did not read the full text of either, so this page relies on manufacturer and distributor summaries and says they are approximate.

Sources

Retrieved

Approximate mapping — not a certification

These pairings are manufacturer and distributor rules of thumb, not an official conversion. NEMA 250 and IEC 60529 use different tests. Always confirm the rating of the specific enclosure with its manufacturer. TNAADO is not affiliated with NEMA, IEC or any company named.