Electrical · Enclosure ratings

IP rating chart and decoder.

Type a code such as IP67, IPX4 or IP66/IP68. The two digits are read separately, with the traps flagged.

Short answer: IP is followed by a dust digit (0 to 6) and a water digit (0 to 9). IP67 is dust-tight and passed a 30-minute immersion test; IP68 is dust-tight with immersion conditions set by the manufacturer. An X means not rated, and IPX7 does not imply IPX6.

Digits from IEC 60529 as published by two readable referencesRetrieved 20 October 2026

Advertisement
One code, or a dual rating such as IP66/IP68. Nothing leaves this page.

Result

Enter a code such as IP67 and press Decode.

Advertisement

How to read an IP code

An IP code is the letters IP followed by two characters. The first describes protection against solid objects and dust, on a scale from 0 to 6. The second describes protection against water, from 0 to 9. In IP65, the 6 says the enclosure is dust-tight and the 5 says it survives water jets. Either position can be replaced by the letter X, which means that category was not tested or not rated. IPX4 therefore says nothing about dust, and IP6X says nothing about water.

The code comes from IEC 60529. The standard itself is sold, not published, so this page is built from two readable references that agree with each other: the Index Enclosures IP ratings guide and the Wikipedia article on the IP Code, with a third chart from a pump maker cross-checking the digit wording. Where a reference was thin we said less rather than more.

The chart

First digit: solids and dust

DigitProtected against
0Nothing in particular.
1Objects larger than 50 mm, such as the back of a hand.
2Objects larger than 12.5 mm, such as fingers.
3Objects larger than 2.5 mm, such as tools and thick wires.
4Objects larger than 1 mm, such as most wires and slender screws.
5Dust-protected: dust may enter, but not enough to interfere with the equipment.
6Dust-tight: no dust enters.

Second digit: water

DigitProtected against
0Nothing in particular.
1Vertically dripping water.
2Dripping water with the enclosure tilted 15 degrees.
3Spray at any angle up to 60 degrees from vertical.
4Splashing from any direction.
5Water jets from a 6.3 mm nozzle.
6Powerful jets from a 12.5 mm nozzle.
7Temporary immersion: lowest point 1 m under the surface (or highest point 150 mm under, whichever is deeper) for 30 minutes.
8Continuous immersion under conditions the manufacturer specifies, for 1 m or deeper.
9Close-range, high-pressure, high-temperature spray-downs. The 9K form comes from ISO 20653, not IEC 60529.

IP67 versus IP68 is not simply good versus better

Both are dust-tight. The difference is in the water test. The 7 is a defined test: 30 minutes in water about a metre deep. The 8 is open-ended by design: the standard says the equipment is suitable for continuous immersion under conditions the manufacturer shall specify, and Wikipedia adds that the depth is generally up to 3 metres. So an IP68 device can have been tested deeper, longer or both, or it can have been tested to little more than the IP67 conditions. The code alone cannot tell you which, and the datasheet should state the depth and time. If it does not, treat IP68 as an unanswered question rather than an answer.

Ratings are not cumulative in the way people assume

A higher number does not automatically include the lower tests. Index Enclosures notes that an IP67 device has passed the immersion test but has not necessarily passed the jet tests, and Wikipedia says the same thing in other words: a device that complies with IPX7 is not necessarily compliant with IPX5 or IPX6. That is why you see dual ratings such as IP66/IP68 or IPX5/IPX7. They mean the product passed both tests separately. If you need a device to survive a pressure washer and also a dunking, look for both codes, not for the larger single number.

Worked example

These are hypothetical products. A work light sold as IP65 is dust-tight and survives 6.3 mm water jets from any direction; it has made no claim about immersion, so leaving it in a puddle is outside the rating. A wireless speaker sold as IPX7 passed the 30-minute immersion test, says nothing about dust, and made no jet claim, so a hard hose spray is outside what it promised. A sensor housing marked IP66/IP68 passed both the powerful-jet test and the manufacturer-defined immersion test, and the datasheet should give the immersion depth and duration. Type any of these codes into the decoder and it prints each digit in plain words.

Common mistakes

Who this is for

Anyone choosing outdoor lighting, a camera, a junction box, a phone, a sensor or a speaker and trying to see what a printed code does and does not promise. Installers can use it to compare a European-marked product against a North American specification, then move to the NEMA to IP crosswalk if the specification is written in NEMA types.

What this does not cover

Advertisement

Frequently asked questions

What does IP65 mean?

The 6 means dust-tight and the 5 means protected against water jets from a 6.3 mm nozzle from any direction. It makes no claim about immersion.

What is the difference between IP67 and IP68?

Both are dust-tight. IP67 passed the defined immersion test, about 1 m for 30 minutes. IP68 passed immersion under conditions the manufacturer states, for 1 m or deeper, so the datasheet must say the depth and time.

Is IP68 better than IP67?

Not automatically. The 8 level has no fixed depth in the standard, so an IP68 product may be tested deeper or longer than IP67, but the code alone does not prove it.

What does IPX4 mean?

The water digit is 4, which means splashing water from any direction has no harmful effect. The X means dust protection was not rated, so the code says nothing about dust.

What does the X in IPX7 mean?

It means that category was not tested or rated. It does not mean there is no protection, only that no claim is made.

Does IPX7 mean a device also survives water jets?

No. Immersion levels do not imply the jet levels. A device passing IPX7 is not necessarily compliant with IPX5 or IPX6, which is why dual ratings like IPX5/IPX7 exist.

What is IP69K?

A high-pressure, high-temperature wash-down test from ISO 20653, the road-vehicle standard that replaced DIN 40050-9. IEC 60529 itself defines level 9 without the K.

Is an IP rating the same as a NEMA rating?

No. They use different tests and NEMA adds requirements such as corrosion resistance. NEMA to IP mappings are approximate and only run in one direction.

Sources

Retrieved

Reference only — not a certification check

This page explains what an IP code claims. It does not verify that a product was tested or by whom. The standard, IEC 60529, is sold by IEC; for compliance work use the standard and the manufacturer’s certificate. TNAADO is not affiliated with IEC or any manufacturer named.