U.S. · Workplace safety · 29 CFR 1910.1000

Carbon dioxide OSHA PEL checker.

The Table Z-1 limit for carbon dioxide is 5000 ppm. Enter a reading to compare it with the printed figure.

The OSHA permissible exposure limit for carbon dioxide in 29 CFR 1910.1000 Table Z-1 is 5000 ppm (9000 mg/m3, approximate), an 8-hour time weighted average. The CAS number listed is 124-38-9 and the Skin designation column is blank.

Source: 29 CFR 1910.1000, Table Z-1Read November 2, 2026Unofficial reference

Advertisement

Your reading

Paragraph (a)(2) compares this to the 8-hour TWA, computed as in paragraph (d)(1).
The mg/m3 figure in the table is approximate for this row (footnote (b)).

Result

Advertisement

The carbon dioxide row in Table Z-1

The table below reproduces the Carbon dioxide row of Table Z-1, Limits for Air Contaminants, in 29 CFR 1910.1000 as published in the eCFR. Values are shown exactly as the table prints them.

SubstanceCAS No. (c)ppm (a) 1mg/m3 (b) 1Skin designation
Carbon dioxide124-38-950009000

Reading the footnotes

The column headings carry footnote markers. The eCFR prints them as follows.

For this row that means the ppm column is the figure expressed by volume at 25 °C and 760 torr, the mg/m3 figure is the approximate mass equivalent, and the name in the first column, not the CAS number, is what enforcement is based on.

Why this entry is an 8-hour average

Neither number in the carbon dioxide row is preceded by (C), so footnote 1 treats it as an 8-hour TWA. Paragraph (a)(2) of the section reads: “An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.”

Entries that are preceded by (C) in the table are ceiling values under paragraph (a)(1), which says exposure shall at no time exceed the printed limit.

Skin designation

The Skin designation column for carbon dioxide is blank in the eCFR table.

Worked example

Illustration of the paragraph (d)(1) arithmetic only, with invented readings. Suppose one employee's shift has two hours at 7500 ppm, two hours at 3750 ppm and four hours at 2500 ppm of carbon dioxide. Then E = (2 × 7500 + 2 × 3750 + 4 × 2500) ÷ 8 = 4062.5 ppm. Compared with the printed 5000 ppm 8-hour limit, 4062.5 ppm is below it. The same method is the one the CFR uses in its own Substance A example for a 100 ppm limit, which comes to 81.25 ppm.

Computation formulae in paragraph (d)

Paragraph (d)(1)(i) gives the cumulative exposure formula for an 8-hour shift: E = (Ca Ta + Cb Tb + . . .Cn Tn) ÷ 8, where E is the equivalent exposure for the working shift, C is the concentration during any period of time T where the concentration remains constant, and T is the duration in hours of the exposure at the concentration C. The value of E shall not exceed the 8-hour time weighted average specified in subpart Z of 29 CFR part 1910 for the substance involved.

Paragraph (d)(2)(i) gives the formula for mixtures: In case of a mixture of air contaminants an employer shall compute the equivalent exposure as follows: Em = (C1 ÷ L1 + C2 ÷ L2) + . . .(Cn ÷ Ln), where C is the concentration of a particular contaminant and L is the exposure limit for that substance specified in subpart Z of 29 CFR part 1910. The value of Em shall not exceed unity (1). The paragraph introducing these formulae applies them to substances for which 8-hour time weighted averages are listed.

What paragraph (e) says about controls

This page does not recommend any exposure-control measure. For reference, paragraph (e) of the section is printed as follows: “To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.”

Limits of this page

This page reads Table Z-1 and the paragraphs of 1910.1000 quoted above. It does not say that an exposure below a printed limit is safe, it does not cover Table Z-2 or Table Z-3 substances, other OSHA substance-specific standards, state-plan rules or recommended limits published by other bodies, and it does not tell you how to sample, how to control exposure or which respirator to use. The checker compares one number you type with the printed figure and applies the “shall not exceed” wording as written, so a reading equal to the limit is not above it. Anything involving a real workplace belongs with a qualified industrial hygienist, your safety data sheet and the OSHA office for your area. The eCFR lists the newest content version of this section as May 30, 2017.

Sources

Sources opened and read November 2, 2026.

Advertisement

Frequently asked questions

What is the OSHA PEL for carbon dioxide?

Table Z-1 prints 5000 ppm and 9000 mg/m3 for carbon dioxide (CAS 124-38-9), an 8-hour time weighted average.

Is the carbon dioxide limit a ceiling or an 8-hour average?

It is an 8-hour time weighted average. The entry has no (C), so paragraph (a)(2) applies: exposure shall not exceed the 8-hour TWA in any 8-hour work shift of a 40-hour work week.

What CAS number does OSHA list for carbon dioxide?

124-38-9. Footnote (c) says the CAS number is for information only and that enforcement is based on the substance name.

Is the 9000 mg/m3 figure exact?

Footnote (b) says that when an entry is in the mg/m3 column only, the value is exact; when listed with a ppm entry, it is approximate. This row has a ppm entry, so the mg/m3 figure is approximate.

Does the carbon dioxide row have a skin designation?

No, the Skin designation column is blank for this row in the eCFR table.

How are exposures to several substances at once computed?

Paragraph (d)(2) of the section gives a mixture formula, Em = C1/L1 + C2/L2 + ... + Cn/Ln, where C is the concentration of each contaminant and L is its limit. The value of Em shall not exceed unity (1).

Does this page say what exposure is safe or how to control it?

No. It quotes the table row and the section text. Paragraph (e) of the section is reproduced on this page as printed; questions about a specific workplace go to a competent industrial hygienist or the OSHA office.

Not legal or compliance advice

This page is general information drawn from the sources listed, not legal, safety, medical or compliance advice, and it is not run by any government agency. Rules, forms and dates change and OSHA or your enforcement officer decides your case, so confirm with the office named on this page before you rely on it. Everything runs in your browser; nothing you enter is sent anywhere.