U.S. · Workplace safety · 29 CFR 1910.1000

Chlorine OSHA PEL checker.

The Table Z-1 limit for chlorine is a ceiling of 1 ppm. Enter a reading to compare it with the printed figure.

The OSHA permissible exposure limit for chlorine in 29 CFR 1910.1000 Table Z-1 is printed as (C)1 ppm and (C)3 mg/m3. The (C) means it is a ceiling limit: exposure shall at no time exceed it, or, if instantaneous monitoring is not feasible, a 15-minute time weighted average shall not exceed it. The CAS number listed is 7782-50-5 and the Skin designation column is blank.

Source: 29 CFR 1910.1000, Table Z-1Read November 2, 2026Unofficial reference

Advertisement

Your reading

Paragraph (a)(1) compares this to the ceiling.
The mg/m3 figure in the table is approximate for this row (footnote (b)).

Result

Advertisement

The chlorine row in Table Z-1

The table below reproduces the Chlorine row of Table Z-1, Limits for Air Contaminants, in 29 CFR 1910.1000 as published in the eCFR. Values are shown exactly as the table prints them.

SubstanceCAS No. (c)ppm (a) 1mg/m3 (b) 1Skin designation
Chlorine7782-50-5(C)1(C)3

Reading the footnotes

The column headings carry footnote markers. The eCFR prints them as follows.

For this row that means the ppm column is the figure expressed by volume at 25 °C and 760 torr, the mg/m3 figure is the approximate mass equivalent, and the name in the first column, not the CAS number, is what enforcement is based on.

Why this entry is a ceiling

Both numbers in the chlorine row are preceded by (C). Paragraph (a)(1) of the section reads: “An employee's exposure to any substance in Table Z-1, the exposure limit of which is preceded by a “C”, shall at no time exceed the exposure limit given for that substance. If instantaneous monitoring is not feasible, then the ceiling shall be assessed as a 15-minute time weighted average exposure which shall not be exceeded at any time during the working day.”

Entries without a (C) are instead 8-hour time weighted averages under paragraph (a)(2).

Skin designation

The Skin designation column for chlorine is blank in the eCFR table.

Worked example

Illustration of the arithmetic only, with invented readings. Suppose a 15-minute sampling run is used because instantaneous monitoring is not feasible, and the result is 0.6 ppm. Paragraph (a)(1) assesses that result against the printed 1 ppm: 0.6 ppm is below it. A 15-minute result of 1.2 ppm would be above the printed 1 ppm. The conclusion from a single result is only whether it is above or below the printed figure; it does not show how the rest of the shift looked. Because the entry is a ceiling, a short low reading earlier in the shift does not average away a later higher one; the text says exposure shall at no time exceed the limit.

Computation formulae in paragraph (d)

Paragraph (d)(1)(i) gives the cumulative exposure formula for an 8-hour shift: E = (Ca Ta + Cb Tb + . . .Cn Tn) ÷ 8, where E is the equivalent exposure for the working shift, C is the concentration during any period of time T where the concentration remains constant, and T is the duration in hours of the exposure at the concentration C. The value of E shall not exceed the 8-hour time weighted average specified in subpart Z of 29 CFR part 1910 for the substance involved.

Paragraph (d)(2)(i) gives the formula for mixtures: In case of a mixture of air contaminants an employer shall compute the equivalent exposure as follows: Em = (C1 ÷ L1 + C2 ÷ L2) + . . .(Cn ÷ Ln), where C is the concentration of a particular contaminant and L is the exposure limit for that substance specified in subpart Z of 29 CFR part 1910. The value of Em shall not exceed unity (1). The paragraph introducing these formulae applies them to substances for which 8-hour time weighted averages are listed.

What paragraph (e) says about controls

This page does not recommend any exposure-control measure. For reference, paragraph (e) of the section is printed as follows: “To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.”

Limits of this page

This page reads Table Z-1 and the paragraphs of 1910.1000 quoted above. It does not say that an exposure below a printed limit is safe, it does not cover Table Z-2 or Table Z-3 substances, other OSHA substance-specific standards, state-plan rules or recommended limits published by other bodies, and it does not tell you how to sample, how to control exposure or which respirator to use. The checker compares one number you type with the printed figure and applies the “shall not exceed” wording as written, so a reading equal to the limit is not above it. Anything involving a real workplace belongs with a qualified industrial hygienist, your safety data sheet and the OSHA office for your area. The eCFR lists the newest content version of this section as May 30, 2017.

Sources

Sources opened and read November 2, 2026.

Advertisement

Frequently asked questions

What is the OSHA PEL for chlorine?

Table Z-1 prints (C)1 ppm and (C)3 mg/m3, a ceiling limit, for chlorine (CAS 7782-50-5).

Is the chlorine limit a ceiling or an 8-hour average?

It is a ceiling. The (C) in front of the value denotes a ceiling limit, and paragraph (a)(1) says exposure shall at no time exceed it.

What CAS number does OSHA list for chlorine?

7782-50-5. Footnote (c) says the CAS number is for information only and that enforcement is based on the substance name.

Is the 3 mg/m3 figure exact?

Footnote (b) says that when an entry is in the mg/m3 column only, the value is exact; when listed with a ppm entry, it is approximate. This row has a ppm entry, so the mg/m3 figure is approximate.

Does the chlorine row have a skin designation?

No, the Skin designation column is blank for this row in the eCFR table.

How are exposures to several substances at once computed?

Paragraph (d)(2) of the section gives a mixture formula, Em = C1/L1 + C2/L2 + ... + Cn/Ln, where C is the concentration of each contaminant and L is its limit. The value of Em shall not exceed unity (1).

Does this page say what exposure is safe or how to control it?

No. It quotes the table row and the section text. Paragraph (e) of the section is reproduced on this page as printed; questions about a specific workplace go to a competent industrial hygienist or the OSHA office.

Not legal or compliance advice

This page is general information drawn from the sources listed, not legal, safety, medical or compliance advice, and it is not run by any government agency. Rules, forms and dates change and OSHA or your enforcement officer decides your case, so confirm with the office named on this page before you rely on it. Everything runs in your browser; nothing you enter is sent anywhere.