Van battery bank size calculator.

List what you run each day, choose how many days you want to last without charging, and see how many watt-hours and amp-hours of battery that takes.

Advertisement

Inputs

Anything not listed above.
Days you want to run with no solar, alternator or shore charging.
Battery University notes manufacturers often rate batteries at 80% depth of discharge. For lead-acid, 50% is a common rule of thumb, not a published standard.
Loss through an inverter or DC converter. Use 100 if everything is native 12V DC.

Battery bank needed

Enter your numbers.

How to size a van battery bank

Add up watts times hours for each load to get daily watt-hours (Wh). Battery Wh needed = daily Wh x days of autonomy / usable depth of discharge / conversion efficiency. Amp-hours = watt-hours / battery volts. Watts times hours giving watt-hours is the standard electricity unit relationship described by the U.S. EIA.

Worked example. The default loads add up to 875 Wh a day (fridge 45 W x 8 h, lights 20 W x 4 h, fan 25 W x 6 h, laptop 60 W x 4 h, devices 15 W x 3 h). For 2 days at 12 V, 80% usable and 90% efficiency: 875 x 2 / 0.8 / 0.9 = 2,431 Wh, which is 203 Ah at 12 V. A steady 200 W load would run that bank for 8.8 hours.

Rule-of-thumb inputs. The loads in the example are placeholders, not typical figures. Read the watts off your own appliances. The 50% lead-acid figure is a common rule of thumb, not a published standard. Cold weather, battery age and high discharge rates reduce real capacity.

The method, step by step

  1. Daily watt-hours. For each load, watts × hours used per day. Add them up, plus any fixed daily energy you enter separately. The U.S. EIA defines a watt-hour as one watt used for one hour; its example is a 40-watt bulb for five hours, 200 Wh.
  2. Days of autonomy. Multiply by how many days the battery must last without recharging.
  3. Usable depth of discharge. Divide by the fraction you are willing to use. Battery University notes that manufacturers often rate a battery at 80 percent depth of discharge, and that shallower cycling lengthens service life.
  4. Conversion efficiency. Divide by the efficiency of any inverter or converter in the path.
  5. Convert to amp-hours. Ah = Wh ÷ battery volts.

Worked examples

Default loads. The default list totals 875 Wh a day. For 2 days at 80% usable and 90% efficiency the bank is 875 × 2 ÷ 0.80 ÷ 0.90 = 2,431 Wh, about 203 Ah at 12 V. A steady 200 W load would run for 8.8 hours.

A more cautious bank. If only 50% is treated as usable (a common rule of thumb for lead-acid, not a published standard) and you plan just one day, the same loads need 875 ÷ 0.50 ÷ 0.90 = 1,944 Wh, about 162 Ah. Planning 1 day on a 50% limit needs fewer amp-hours than 2 days at 80%, so the choice of days of autonomy matters as much as chemistry.

12 V versus 24 V. A bank for 1,200 Wh a day, 3 days, 90% usable and 90% efficient needs 1,200 × 3 ÷ 0.9 ÷ 0.9 = 4,444 Wh. That is 370 Ah at 12 V but 185 Ah at 24 V. The energy is the same; the amp-hour number halves when the voltage doubles. This is why you should compare batteries in watt-hours, not amp-hours alone.

How to calculate the watt-hours of a power bank

Watt-hours = milliamp-hours × voltage ÷ 1,000. A power bank labelled 20,000 mAh at a 3.7 V cell voltage holds 20,000 × 3.7 ÷ 1,000 = 74 Wh. Its capacity is quoted at the cell voltage, not the 5 V a phone charges at, and conversion losses mean you get less than that to your devices. If the case prints a Wh figure, use it. The power bank phone charges calculator does this for a phone.

Choosing the numbers honestly

  • Read the watts off your own appliances. Fridges and fans cycle, so use the average draw and actual hours.
  • Add margin for the loads you forget and for cold weather, which reduces available capacity.
  • Use the manufacturer's usable-capacity or depth-of-discharge figure for your chemistry rather than a rule of thumb.

What the calculator does not cover

It sizes storage only. Charging, cables, fusing and the inverter are separate decisions: see the van solar panel size calculator, the van inverter size calculator and the solar charge time calculator. Aged batteries, very high discharge rates and low temperatures reduce real capacity.

Frequently asked questions

How many amp-hours of battery do I need for a van?

Add up your daily watt-hours, multiply by the days you want to last, divide by usable depth of discharge and efficiency, then divide by battery volts. With the example loads and 2 days that is about 203 Ah at 12 V.

How do I convert watt-hours to amp-hours?

Divide watt-hours by the battery voltage. 2,431 Wh at 12 V is 203 Ah.

What depth of discharge should I use?

Battery University notes manufacturers often rate a battery at 80% depth of discharge. Use your battery maker's own figure. For lead-acid, 50% is a common rule of thumb, not a published standard.

Why include conversion efficiency?

An inverter or DC converter wastes some energy as heat, so the battery must supply more than the appliance uses. Use 100% if everything runs directly on 12V DC.

How do I calculate the watt-hours of a power bank?

Multiply milliamp-hours by the battery's voltage and divide by 1,000. For a 20,000 mAh pack at 3.7 V that is 74 Wh. Usable energy is lower after conversion losses, so prefer a Wh figure printed on the pack.

Should I use a 12 V or 24 V battery bank?

The energy you need in watt-hours is the same, but a 24 V bank needs half the amp-hours and carries half the current for a given load. Choose based on your inverter, charger and wiring, and compare batteries in Wh.

How many days of autonomy should I plan for?

It depends on how often you can recharge from solar, alternator or shore power. One day is enough if you drive daily; two to three days builds in cloudy-weather margin but adds weight and cost.

Why does the runtime check use usable energy?

Runtime is the usable energy that reaches the load divided by the load. The tool multiplies the nameplate energy by depth of discharge and efficiency before dividing by the steady load you enter.

Sources

Checked (additional source retrieved 2026-10)

Runs entirely in your browser. Nothing you type is sent or stored.

Planning estimate, not professional advice

Results are planning estimates from the numbers you enter. They are not professional, engineering, electrical or safety advice and are not a substitute for the manufacturer's instructions or local code. Battery banks, inverters and DC wiring can start fires or injure you if built wrongly: size cable and fuses to the equipment manual, fuse every positive conductor close to the battery, and have a qualified electrician check the build.

Advertisement
Advertisement