Home energy · solar planning
Solar payback, with your assumptions.
Use an annual production estimate from PVWatts or an installer quote, then change the rates that actually apply to you.
Inputs
Payback estimate
How it works
First-year value is production × [self-use × grid rate + exported energy × export rate], less maintenance. The modeled payback repeats that calculation for 40 years while applying the entered annual degradation.
PVWatts is an NREL/DOE production model, and its own documentation cautions that outputs include assumptions and uncertainty. This calculator does not model financing, incentives, taxes, curtailment, utility fixed charges or future rate changes.
Source: NREL PVWatts · PVWatts technical reference
How the payback is calculated, input by input
- Value of each kWh. Solar energy used on-site avoids the grid rate; the rest is exported at the export credit. The blended value per kWh = self-use share × grid rate + (1 − self-use share) × export rate.
- First-year gross value = annual production × blended value. First-year net subtracts annual maintenance.
- Simple payback = installed cost ÷ first-year net savings. It assumes every year equals the first.
- Modelled payback repeats the savings for up to 40 years, reducing production by the degradation rate each year, and finds when cumulative savings reach the cost.
Worked example with the default inputs
An $18,000 system produces 6,500 kWh a year, 60% used on-site at $0.18 and 40% exported at $0.08. The blended value is 0.6 × 0.18 + 0.4 × 0.08 = $0.14 per kWh. First-year gross value is 6,500 × 0.14 = $910, and $760 after $150 maintenance. Simple payback is 18,000 ÷ 760 = 23.7 years. With 0.5% annual degradation the modelled payback is 25.5 years, because later years save slightly less. The 40-year total savings come to about $27,066. All figures are illustrative, not market data.
Which input moves the answer most
Holding everything else at the defaults, here is what changing one input does to the result:
| Change | Simple payback | Modelled payback |
|---|---|---|
| Defaults (60% self-use, $0.18 grid rate, $18,000) | 23.7 years | 25.5 years |
| 100% of production used on-site | 17.6 years | 18.6 years |
| System cost $14,000 (for example after a confirmed incentive) | 18.4 years | 19.5 years |
| Grid rate $0.12 instead of $0.18 | 34.2 years | 38.6 years |
The avoided grid rate and the share of solar you use yourself matter more than small changes to maintenance or degradation. A system that mostly exports at a low credit pays back far more slowly than one that offsets expensive grid electricity.
Where to get annual production
Do not guess from the panel rating. Use an installer's simulation or a modelling tool for your roof's tilt, direction and shading. The PVWatts calculator estimates production for a location, and its manual states the results are a representative estimate with errors that may reach ±10% for annual totals and ±30% for monthly totals against typical weather, with a single year deviating up to ±20% from the long-term average. Natural Resources Canada's photovoltaic potential maps give kWh per kW of installed capacity for any Canadian location, built on a performance ratio of 0.75 for grid-connected systems without batteries.
Choosing a degradation rate
A widely cited NREL review by Jordan and Kurtz assembled nearly 2,000 reported degradation rates from field testing over 40 years and found a median of 0.5% per year, the tool's default. Individual systems vary, and a manufacturer's warranty states its own guaranteed output decline.
Common mistakes
- Entering the system's kW rating where annual kWh is expected.
- Valuing exports at the retail rate when your utility pays a lower credit, or applying a credit that ignores net metering limits.
- Mixing currencies or including incentives you have not confirmed.
- Forgetting that costs such as an inverter replacement are not in the maintenance line unless you add them.
What this tool leaves out
Financing interest, taxes, future electricity rate changes, utility fixed charges, curtailment and incentives are not modelled. If a battery or time-of-use rates change the value of each kWh, adjust the blended inputs yourself. Compare the result with the solar panel annual yield calculator for a production sanity check, and the heat pump savings calculator for another efficiency project.
Frequently asked questions
How do I calculate solar panel payback?
Divide the installed cost, minus any confirmed incentives, by the annual savings. Annual savings are production times a blended value per kWh (self-used energy at the grid rate, exported energy at the export credit), minus maintenance. With the defaults that is 18,000 ÷ 760 = 23.7 years.
Why is the modelled payback longer than the simple payback?
The simple payback assumes the first year's savings repeat forever. The modelled payback reduces production each year by the degradation rate, so cumulative savings accumulate a little more slowly.
What is a good solar payback period?
There is no universal threshold. Compare the payback with the warranty period and expected life of the equipment, and with other uses of the same money. A short payback usually means high grid rates and a high share of solar used on-site.
What degradation rate should I use?
The tool defaults to 0.5% per year, which matches the median reported in the NREL review of nearly 2,000 field degradation rates. Your panel warranty may guarantee a specific decline, so check it.
How do I find annual solar production for my home?
Ask your installer for a site-specific simulation or run a production tool such as PVWatts, which estimates energy for a location, tilt and orientation. Natural Resources Canada's PV potential maps give kWh per kW for Canadian locations.
Does this include rebates, financing or tax effects?
No. To include a rebate, subtract it from the installed cost yourself. Financing interest, taxes, rate increases and utility fixed charges are not modelled.
What if my utility pays a different export credit?
Change the export credit and self-use fields to match your utility's rules. Net metering and buyback terms vary by utility and can change, so read your own agreement.
Sources
Retrieved
Every link below was opened and read in October 2026. The note after each link says which statement on this page it supports.
- PVWatts Calculator (retrieved 2026-10): production estimates by location, tilt and orientation
- PVWatts Version 5 Manual (OSTI) (retrieved 2026-10): stated error ranges of ±10% annual and ±30% monthly; ±20% year-to-year deviation
- Jordan and Kurtz, Photovoltaic Degradation Rates: An Analytical Review (OSTI) (retrieved 2026-10): median degradation of 0.5% per year across nearly 2,000 reported rates
- Natural Resources Canada, Photovoltaic potential and solar resource maps of Canada (retrieved 2026-10): kWh per kW potential for any Canadian location; performance ratio of 0.75 for grid-connected systems without batteries