Home energy · solar planning

Solar panel annual yield, in kWh.

Turn system size, peak sun hours and system losses into a yearly production figure you can check against an installer quote.

Advertisement

Inputs

Total panel nameplate rating, e.g. 15 panels x 400 W = 6 kW.
Look up your location in NREL PVWatts (its average daily plane-of-array value, kWh/m²/day) or use your installer's figure.
PVWatts default is 14%, a 0.86 factor.
PVWatts treats this separately from system losses; its nominal value is 96%. Enter 100 to apply only the loss factor.

Annual yield estimate

Advertisement

Formula

Annual kWh = system kW DC × peak sun hours per day × 365 × (1 − system losses) × inverter efficiency.

Worked example

A 6 kW system at 4.0 peak sun hours: 6 × 4.0 × 365 = 8,760 kWh before losses. At 14% losses that is 8,760 × 0.86 = 7,533.6 kWh; at 96% inverter efficiency, 7,533.6 × 0.96 = about 7,232 kWh per year, or roughly 603 kWh per month.

Where the defaults come from

The 14% total system loss is the NREL PVWatts default, built from soiling (2%), shading (3%), snow (0%), mismatch (2%), wiring (2%), connections (0.5%), light-induced degradation (1.5%), nameplate rating (1%), age (0%) and availability (3%). Individual losses are combined multiplicatively, not added. NREL notes that 1 − 14/100 = 0.86 and that inverter efficiency is a separate input (nominal 96%) not included in the system loss. Peak sun hours equal average daily plane-of-array irradiation in kWh/m²/day, which PVWatts reports by month. Sources checked 2026-09-30 (PVWatts V5 manual, September 2014; the current PVWatts calculator is version 8).

Limits: this is an annual-average shortcut. It ignores seasonal and hourly variation, temperature, tilt and orientation (already folded into the sun-hours figure you enter), clipping and year-over-year degradation. Use PVWatts or an installer's simulation before a purchase decision.

Source: NREL PVWatts Version 5 Manual · PVWatts V1 technical reference (0.77 derate) · PVWatts calculator

What each input means

  • System size (kW DC) is the panels' combined rated output under standard test conditions, the DC nameplate, not the inverter's AC rating. Installers also write it as kWp.
  • Peak sun hours per day is the average daily solar energy on the tilted panel surface in kWh per square metre, because one peak sun hour is one hour at 1 kW/m². It is a measure of energy, not of how many hours the sun is up.
  • System losses (%) are everything between the panel's rating and the DC energy that leaves the array: soiling, shading, snow, mismatch, wiring, connections, light-induced degradation, nameplate tolerance, age and availability.
  • Inverter efficiency (%) converts DC to AC. PVWatts keeps it separate from system losses, with a nominal 96%.

Worked examples

The default. 6 kW × 4.0 sun hours × 365 = 8,760 kWh before losses. At 14% losses and 96% inverter efficiency the result is 8,760 × 0.86 × 0.96 = 7,232 kWh a year, about 603 kWh a month, which is 1,205 kWh per kW installed.

A larger system on a duller site. 8 kW at 3.5 sun hours gives 8 × 3.5 × 365 = 10,220 kWh before losses and 8,438 kWh after, or 1,055 kWh per kW. A bigger array does not guarantee a bigger yield per kW; the sun-hours figure does most of the work.

What higher losses cost. Raise losses on the 6 kW default from 14% to 20% (heavy shading or snow) and the output falls to 6,728 kWh, roughly 504 kWh less each year. With no losses and a perfect inverter the same array would produce 8,760 kWh, which no real system achieves.

Where the 14% comes from

PVWatts' default system losses are built from per-mechanism defaults: soiling 2%, shading 3%, snow 0%, mismatch 2%, wiring 2%, connections 0.5%, light-induced degradation 1.5%, nameplate rating 1%, age 0% and availability 3%. The manual states that the total loss is not the sum of the individual losses but their product, giving 14% and a derate of 0.86; multiplying by the nominal 96% inverter efficiency gives an overall factor of about 0.825. Replace the default when you have evidence, such as a measured shading study.

How to sanity-check the answer

Compare kWh per kW installed with a trusted regional figure. Natural Resources Canada's photovoltaic potential maps report expected average electricity production per kilowatt of installed DC capacity for any location in Canada, using a performance ratio of 0.75 for grid-connected systems without batteries; its data come from 1974 to 1993 insolation records and the page calls the potential a first-order approximation. If your number is far from that, check your sun hours or losses. For a purchase decision, run PVWatts, whose manual states that results are a representative estimate with errors that may reach ±10% for annual totals and ±30% for monthly totals against typical weather, and a single year can differ from the long-term average by up to ±20%.

Why your installer's number might differ

  • They model hourly weather, tilt, azimuth and temperature rather than one annual average.
  • They may assume different shading, soiling or snow losses.
  • They may report AC output while you compare to DC, or use a different inverter efficiency.
  • They may count the system's first-year output, while this calculator ignores degradation over time.

What this tool leaves out

Seasonal and hourly variation, temperature effects, clipping from an undersized inverter and year-over-year degradation are outside an annual-average shortcut. Use the solar payback calculator to turn a yield into a financial estimate, and the solar charge time calculator for battery charging.

Sources

Retrieved

Every link below was opened and read in October 2026. The note after each link says which statement on this page it supports.

Advertisement

FAQ

What are peak sun hours?

The number of hours per day at 1 kW/m² that would deliver the same energy as the day's real sunlight. It is the same number as daily irradiation in kWh/m²/day.

What system losses should I use?

Start with PVWatts' 14%. Raise it for heavy shading or snow and lower it only if your installer documents why.

Is this the same as a PVWatts result?

No. PVWatts simulates hourly weather for your location. This tool multiplies annual averages, so use it as a quick check on a quote.

What is a good kWh per kW for solar panels?

There is no single good number because it depends on location, tilt and shading. Compare your result with a regional figure, for example Natural Resources Canada's photovoltaic potential maps for Canadian locations, or run PVWatts for your address.

What is the difference between kW and kWh in solar?

kW is power, the rate of production at a moment, and describes the system's size. kWh is energy, production over time. A 6 kW system producing 7,232 kWh a year does not produce 6 kWh every hour.

Can I use the sun hours from a weather website?

Be careful. The input should be daily irradiation on the tilted panel surface in kWh/m², not a count of daylight hours or flat-ground (horizontal) irradiation, which can differ for a tilted array. PVWatts reports plane-of-array solar radiation by month.

How many panels is a 6 kW system?

Divide 6,000 W by the panel's rated watts. With 400 W panels that is 15 panels; with 500 W panels it is 12. Check the rating on the data sheet of the panel you are quoted.