Insulation Calculator

Estimate how many fiberglass batts you need for a wall or attic, based on standard 16" or 24" on-center framing. Includes recommended R-values by climate zone from ENERGY STAR / the 2021 IECC.

Advertisement

Inputs

Area to insulate
Insulation & waste

Batts needed

Fill the form and press Calculate.

Recommended R-values by climate zone

Batt count here is pure geometry (area ÷ coverage per batt). How much R-value you actually need depends on where the wall or attic is. The table below is ENERGY STAR's published guidance, based on the 2021 International Energy Conservation Code (IECC) Table R402.1.3.

U.S. IECC climate zones 1 (warmest) through 8 (coldest). Canadian builds should confirm against the National Building Code / local energy code — it sets its own zone map and can call for more than a U.S. zone of similar latitude.
AssemblyZone 1–3Zone 4Zone 5–8
Attic (uninsulated)R30–R49R49–R60R49–R60
Attic (existing 3–4")R25–R49R49R49
Floor over unheated spaceR13–R25R30R30–R38
Wall sheathing (re-siding)R5 (zone 3 only)R5–R10R5–R10
Basement/crawlspace wallR5 sheathing or R13 battR10 sheathing or R13 battR15 sheathing or R19 batt

Batt size varies by manufacturer and package. The 93" length above is typical for an 8 ft wall; adjust it to match the batts you're buying before you order.

Worked example: 500 sq ft of wall at 16 in framing

Batts for 16 in framing are 15 in wide; a 93 in batt covers (15 × 93) ÷ 144 = 9.69 sq ft. With 10% waste the area becomes 550 sq ft, and 550 ÷ 9.69 = 56.8, rounded up to 57 batts, covering about 552 sq ft. For 24 in framing the batts are 23 in wide and each covers 14.85 sq ft, so the same wall needs 38 batts.

Sources and method

Checked

Batt width and length vary by manufacturer. Change the length to match the package. Figures as of October 26, 2026.

Common mix-ups

  1. U.S. DOE: Guide to Home Insulation (Energy Renovations: Insulation)

Checked against these sources on .

Frequently asked questions

How many batts do I need?

Divide the area, plus waste, by the coverage of one batt. Coverage is batt width times length: 15 in wide for 16 in framing, 23 in wide for 24 in framing.

Does a higher R-value need more batts?

No. R-value changes the thickness and rating, not the coverage. Count is the same; the code decides what R-value you need.

How much waste should I allow?

The default is 10%, which covers cuts around windows, outlets and framing. Complicated walls with many cuts may need more.

Can I use this for the attic floor?

Yes for batts between joists, using the joist spacing. Blown-in insulation is sold by coverage and depth, which this tool does not calculate.