OSHA 1910.36 exit routes.

Design and construction requirements for workplace exit routes, quoted from the eCFR.

29 CFR 1910.36(b)(1) says at least two exit routes must be available in a workplace to permit prompt evacuation, located as far away as practical from each other, except where a single exit route is permitted under (b)(3). Exit route doors must be openable from the inside at all times without keys, tools, or special knowledge (paragraph (d)(1)), and the ceiling of an exit route must be at least seven feet six inches high (paragraph (g)(1)).

Source: 29 CFR 1910.36, Subpart ERead November 2, 2026Unofficial reference

Advertisement
Advertisement

At a glance

These rows are taken from the text of 29 CFR 1910.36 as read in the eCFR on November 2, 2026. The paragraph column shows where each appears.

ItemWhat the text saysParagraph
Fire resistance of exit separationOne-hour rating if the exit connects three or fewer stories; two-hour rating if four or more stories(a)(2)
Number of exit routesAt least two, unless a single exit route lets all employees evacuate safely(b)(1), (b)(3)
Exit doorOpenable from the inside at all times without keys, tools, or special knowledge(d)(1)
Door swingMust swing out in the direction of exit travel if the room is designed for more than 50 people or is a high hazard area(e)(2)
Ceiling heightAt least seven feet six inches (2.3 m); projections not lower than six feet eight inches (2.0 m)(g)(1)
Exit access widthAt least 28 inches (71.1 cm) at all points(g)(2)
Outdoor route dead endNot longer than 20 feet (6.2 m)(h)(4)

Basic requirements: paragraph (a)

Number of exit routes: paragraph (b)

Exit discharge: paragraph (c)

Exit doors: paragraphs (d) and (e)

The text on locking and door swing.

Capacity, height and width: paragraphs (f) and (g)

Outdoor exit routes: paragraph (h)

Limits of this page

This page quotes all of 1910.36 as printed in the eCFR. Other exit route sections, which are separate and not reproduced here, sit alongside it in the same subpart. The text points to NFPA 101-2009 and IFC-2009 for the number of exit routes and occupant load. This page does not tell you whether a specific building complies; that is a question for a qualified fire protection professional, the authority having jurisdiction or the OSHA office. The text was requested from the eCFR as of October 29, 2026; the version history linked under Sources shows when the section last changed.

Sources

Sources opened and read November 2, 2026.

Advertisement

Frequently asked questions

How many exit routes does a workplace need?

Paragraph (b)(1): at least two exit routes must be available in a workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3). More than two are required under (b)(2) where all employees would not be able to evacuate safely.

Can a workplace have a single exit route?

Paragraph (b)(3): a single exit route is permitted where the number of employees, the size of the building, its occupancy, or the arrangement of the workplace is such that all employees would be able to evacuate safely during an emergency.

Can an exit door be locked?

Paragraph (d)(1): employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. Paragraph (d)(3) allows locking from the inside only in mental, penal, or correctional facilities, and then only with supervisory personnel continuously on duty and an employer plan to remove occupants during an emergency.

Which way must an exit door swing?

Paragraph (e): a side-hinged door must be used to connect any room to an exit route, and it must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or is a high hazard area.

How wide and how high must an exit route be?

Paragraph (g)(2): an exit access must be at least 28 inches (71.1 cm) wide at all points. Paragraph (g)(1): the ceiling must be at least seven feet six inches (2.3 m) high, and any projection must not reach a point less than six feet eight inches (2.0 m) from the floor.

What fire resistance rating separates an exit?

Paragraph (a)(2): a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories.

What extra rules apply to outdoor exit routes?

Paragraph (h) requires guardrails where a fall hazard exists, cover where snow or ice is likely to accumulate (unless removal is demonstrated), a reasonably straight and substantially level walkway, and no dead-end longer than 20 feet (6.2 m).

Not legal or compliance advice

This page is general information drawn from the sources listed, not legal, safety, medical or compliance advice, and it is not run by any government agency. Rules, forms and dates change and OSHA or your enforcement officer decides your case, so confirm with the office named on this page before you rely on it. Nothing you do on this page is sent anywhere.