U.S. · Vehicle safety · 49 CFR 571.305
FMVSS 305: Electric-Powered Vehicles: Electrolyte Spillage and Electrical Shock Protection explained.
Purpose, scope, application and key requirements of 49 CFR 571.305, quoted from the eCFR, with a finder for its 47 section headings.
FMVSS 305 is the federal motor vehicle safety standard at 49 CFR 571.305. Its text states its scope as: This standard specifies requirements for limitation of electrolyte spillage and retention of electric energy storage/conversion devices during and after a crash, and protection from harmful electric shock during and after a crash and during normal vehicle operation. The standard has 9 top-level sections and 47 numbered headings in all.
Find a section
What FMVSS 305 says it is for
The eCFR heads this section "Standard No. 305; electric-powered vehicles: electrolyte spillage and electrical shock protection; applicable unless a vehicle is certified to § 571.305a." Under 49 CFR part 571, the Federal Motor Vehicle Safety Standards are the numbered standards that set safety performance requirements for motor vehicles and equipment. The text below is quoted from 571.305 as current through October 29, 2026.
This standard specifies requirements for limitation of electrolyte spillage and retention of electric energy storage/conversion devices during and after a crash, and protection from harmful electric shock during and after a crash and during normal vehicle operation.
The purpose of this standard is to reduce deaths and injuries during and after a crash that occur because of electrolyte spillage from electric energy storage devices, intrusion of electric energy storage/conversion devices into the occupant compartment, and electrical shock, and to reduce deaths and injuries during normal vehicle operation that occur because of electric shock or driver error.
What it applies to
The application section of the standard says:
This standard applies to passenger cars, and to multipurpose passenger vehicles, trucks, and buses with a gross vehicle weight rating (GVWR) of 4,536 kilograms (kg) or less, that use electrical propulsion components with working voltages greater than 60 volts direct current (VDC) or 30 volts alternating current (VAC), and whose speed attainable over a distance of 1.6 km on a paved level surface is more than 40 km/h, that are manufactured before September 1, 2027.
Applicability is decided by the text of the standard as written, including any exclusions it lists, and by the date-specific rules in it. This page does not decide whether a particular vehicle or item is covered.
How the standard is organized
The eCFR text of 571.305 has these top-level sections:
- S1: Scope
- S2: Purpose
- S3: Application
- S4: Definitions
- S5: General requirements
- S6: Test requirements
- S7: Test conditions
- S8: Test procedure for on-board electrical isolation monitoring system
- S9: Test methods for physical barrier protection from electric shock due to direct and indirect contact with high voltage sources
In all, the text has 47 numbered headings. Use the finder above to search them; for example, a search for "test" lists the headings that mention tests.
Second-level headings at a glance
These are the numbered sub-sections one level below the top, in order (first 18 of 18):
- S5.1 Electrolyte spillage from propulsion batteries
- S5.2 Electric energy storage/conversion device retention
- S5.3 Electrical safety
- S5.4 Electrical safety during normal vehicle operation
- S6.1 Frontal barrier crash
- S6.2 Rear moving barrier impact
- S6.3 Side moving deformable barrier impact
- S6.4 Post-impact test static rollover
- S7.1 Electric energy storage device state-of-charge
- S7.2 Vehicle conditions
- S7.3 Static rollover test conditions
- S7.4 Rear moving barrier impact test conditions
- S7.5 Side moving deformable barrier impact test conditions
- S7.6 Electrical isolation test procedure
- S7.7 Voltage measurement
- S9.1 Test method to evaluate protection from direct contact with high voltage sources
- S9.2 Test method to evaluate protection against indirect contact with high voltage sources
- S9.3 Test method to determine voltage between exposed conductive parts of electrical protection barriers and the electrical chassis and between exposed conductive parts of electrical protection barriers
Key requirements, quoted from the text
These are excerpts from the requirements sections of 571.305, in the order the standard presents them. Long paragraphs are shortened where marked with [...]; the eCFR has the complete text, tables and figures, which this page omits.
S5 General requirements. Each vehicle to which this standard applies, must meet the requirements in S5.1, S5.2, and S5.3 when tested according to S6 under the conditions of S7.
S5.1 Electrolyte spillage from propulsion batteries. Not more than 5.0 liters of electrolyte from propulsion batteries shall spill outside the passenger compartment, and no visible trace of electrolyte shall spill into the passenger compartment. Spillage is measured from the time the vehicle ceases motion after a barrier impact test until 30 minutes thereafter, and throughout any static rollover after a barrier impact test.
S5.2 Electric energy storage/conversion device retention. During and after each test specified in S6 of this standard: (a) Electric energy storage/conversion devices shall remain attached to the vehicle by at least one component anchorage, bracket, or any structure that transfers loads from the device to the vehicle structure, and (b) Electric energy storage/conversion devices located outside the occupant compartment shall not enter the occupant compartment.
S5.3 Electrical safety. After each test specified in S6 of this standard, each high voltage source in a vehicle must meet one of the following requirements: electrical isolation requirements of subparagraph (a), the voltage level requirements of subparagraph (b), or the physical barrier protection requirements of subparagraph (c). (a) The electrical isolation of the high voltage source, determined in accordance with the procedure specified in S7.6, must be greater than or equal to one of the following: (1) 500 ohms/volt for an AC high voltage source; or (2) 100 ohms/volt for an AC high voltage source if it is conductively connected to a DC high voltage source, but only if the AC high voltage source meets the physical barrier protection requirements specified in S5.3(c)(1) and S5.3(c)(2); [...]
S5.4.1.1 Marking. The symbol shown in Figure 6 shall be present on or near electric energy storage devices. The symbol in Figure 6 shall also be visible on electrical protection barriers which, when removed, expose live parts of high voltage sources. The symbol shall be yellow and the bordering and the arrow shall be black. S5.4.1.1.1 The marking is not required for electrical protection barriers that cannot be physically accessed, opened, or removed without the use of tools. Markings are not required for electrical connectors or the vehicle charge inlet.
S5.4.1.2 High voltage cables. Cables for high voltage sources which are not located within electrical protection barriers shall be identified by having an outer covering with the color orange.
S6 Test requirements. Each vehicle to which this standard applies, under the conditions of S7, must be capable of meeting the requirements of any applicable single barrier crash/static rollover test sequence, without alteration of the vehicle during the test sequence. A particular vehicle need not meet further test requirements after having been subjected to a single barrier crash/static rollover test sequence.
S6.1 Frontal barrier crash. The vehicle must meet the requirements of S5.1, S5.2 and S5.3 when it is traveling longitudinally forward at any speed, up to and including 48 km/h, and impacts a fixed collision barrier that is perpendicular to the line of travel of the vehicle, or at any angle up to 30 degrees in either direction from the perpendicular to the line of travel of the vehicle.
S6.2 Rear moving barrier impact. The vehicle must meet the requirements of S5.1, S5.2, and S5.3 when it is impacted from the rear by a barrier that conforms to S7.3(b) of 571.301 of this chapter and that is moving at any speed up to and including 80 km/h (50 mph) with dummies in accordance with S6.2 of 571.301 of this chapter.
S6.3 Side moving deformable barrier impact. The vehicle must meet the requirements of S5.1, S5.2 and S5.3 when it is impacted from the side by a barrier that conforms to part 587 of this chapter that is moving at any speed up to and including 54 km/h, with the appropriate 49 CFR part 572 test dummies specified in 571.214 of this chapter.
S6.4 Post-impact test static rollover. The vehicle must meet the requirements of S5.1, S5.2, and S5.3, after being rotated on its longitudinal axis to each successive increment of 90 degrees after each impact test specified in S6.1, S6.2, and S6.3.
S7 Test conditions. When the vehicle is tested according to S6, the requirements of S5.1 through S5.3 must be met under the conditions specified in S7.1 through S7.7. All measurements for calculating voltage(s) and electrical isolation are made after a minimum of 5 seconds after the vehicle comes to rest in tests specified in S6. Where a range is specified, the vehicle must be capable of meeting the requirements at all points within the range.
S7.1 Electric energy storage device state-of-charge. The electric energy storage device shall be at the state-of-charge specified in either subparagraph (a), (b), or (c): (a) At the maximum state-of-charge in accordance with the vehicle manufacturer's recommended charging procedures, as stated in the vehicle owner's manual or on a label that is permanently affixed to the vehicle; or (b) If the manufacturer has made no recommendation for charging procedures in the owner's manual or on a label permanently affixed to the vehicle, at a state-of-charge of not less than 95 percent of the maximum capacity of the electric energy storage device; or (c) If the electric energy storage device(s) is/are rechargeable only by an energy source on the vehicle, at any state-of-charge within the normal operating voltage defined by the vehicle manufacturer.
S7.2 Vehicle conditions. The switch or device that provides power from the electric energy storage/conversion system to the propulsion system is in the activated position or the ready-to-drive position. S7.2.1 The parking brake is disengaged and the transmission, if any, is in the neutral position. In a test conducted under S6.3, the parking brake is set.
S7.2.2 Tires are inflated to the manufacturer's specifications. S7.2.3 The vehicle, including test devices and instrumentation, is loaded as follows: (a) A passenger car is loaded to its unloaded vehicle weight plus its rated cargo and luggage capacity weight, secured in the luggage area, plus the necessary test dummies as specified in S6, restrained only by means that are installed in the vehicle for protection at its seating position. (b) A multipurpose passenger vehicle, truck, or bus with a GVWR of 4536 kg or less is loaded to its unloaded vehicle weight plus the necessary dummies, as specified in S6, plus 136 kg or its rated cargo and luggage capacity weight, whichever is less. Each dummy is restrained only by means that are installed in the vehicle for protection at its seating position.
S7.3 Static rollover test conditions. In addition to the conditions of S7.1 and S7.2, the conditions of S7.4 of Sec. 571.301 of this chapter apply to the conduct of static rollover tests specified in S6.4.
S7.4 Rear moving barrier impact test conditions. In addition to the conditions of S7.1 and S7.2, the conditions of S7.3(b) and S7.6 of 571.301 of this chapter apply to the conducting of the rear moving deformable barrier impact test specified in S6.2.
S8 Test procedure for on-board electrical isolation monitoring system. Prior to any impact test, the requirements of S5.4.4 for the on-board electrical isolation monitoring system shall be tested using the following procedure. (1) The electric energy storage device is at the state-of-charge specified in S7.1. (2) The switch or device that provides power from the electric energy storage/conversion system to the propulsion system is in the activated position or the ready-to-drive position. (3) Determine the isolation resistance, Ri, of the high voltage source with the electrical isolation monitoring system using the procedure outlined in S7.6.2 through S7.6.7. (4) Insert a resistor with resistance Ro equal to or greater than 1/(1/(95 times the working voltage of the high voltage source)−1/Ri) and less than 1/(1/(100 times the working voltage of the high voltage source)−1/Ri) between the positive terminal of the high voltage source and the electrical chassis. (5) The electrical isolation monitoring system indicator shall display a warning visible to the driver seated in the driver's designated seating position.
S9.1 Test method to evaluate protection from direct contact with high voltage sources. (a) Any parts surrounding the high voltage components are opened, disassembled, or removed without the use of tools. (b) The selected access probe is inserted into any gaps or openings of the electrical protection barrier with a test force of 10 N ± 1 N with the IPXXB probe or 1 to 2 N with the IPXXD probe. If the probe partly or fully penetrates into the electrical protection barrier, it is placed in every possible position to evaluate contact with high voltage live parts. If partial or full penetration into the electrical protection barrier occurs with the IPXXB probe, the IPXXB probe shall be placed as follows: starting from the straight position, both joints of the test finger are rotated progressively through an angle of up to 90 degrees with respect to the axis of the adjoining section of the test finger and are placed in every possible position. [...]
S9.2 Test method to evaluate protection against indirect contact with high voltage sources. At the option of the manufacturer, protection against indirect contact with high voltage sources shall be determined using the test method in subparagraph (a) or subparagraph (b). (a) Test method using a resistance tester. The resistance tester is connected to the measuring points (the electrical chassis and any exposed conductive part of electrical protection barriers or any two simultaneously reachable exposed conductive parts of electrical protection barriers that are less than 2.5 meters from each other), and the resistance is measured using a resistance tester that can supply current levels of at least 0.2 Amperes with a resolution of 0.01 ohms or less. [...]
S9.3 Test method to determine voltage between exposed conductive parts of electrical protection barriers and the electrical chassis and between exposed conductive parts of electrical protection barriers. (a) Connect the voltmeter to the measuring points (exposed conductive part of an electrical protection barrier and the electrical chassis or any two simultaneously reachable exposed conductive parts of electrical protection barriers that are less than 2.5 meters from each other). (b) Measure the voltage. (c) The voltage between two simultaneously reachable exposed conductive parts of electrical protection barriers that are less than 2.5 meters from each other may be calculated using the separately measured voltages between the relevant electrical protection barriers and the electrical chassis.
Defined terms
The standard defines 29 terms in its definitions section; the first 12 are quoted here from the eCFR.
- Automatic disconnect means a device that when triggered, conductively separates a high voltage source from the electric power train or the rest of the electric power train.
- Charge connector is a conductive device that, by insertion into a vehicle charge inlet, establishes an electrical connection of the vehicle to the external electric power supply for the purpose of transferring energy and exchanging information.
- Connector means a device providing mechanical connection and disconnection of high voltage electrical conductors to a suitable mating component, including its housing.
- Direct contact is the contact of persons with high voltage live parts.
- Electric energy storage device means a high voltage source that stores energy for vehicle propulsion. This includes, but is not limited to, a high voltage battery or battery pack, rechargeable energy storage device, and capacitor module.
- Electric energy storage/conversion device means a high voltage source that stores or converts energy for vehicle propulsion. This includes, but is not limited to, a high voltage battery or battery pack, fuel cell stack, rechargeable energy storage device, and capacitor module.
- Electric energy storage/conversion system means an assembly of electrical components that stores or converts electrical energy for vehicle propulsion. This includes, but is not limited to, high voltage batteries or battery packs, fuel cell stacks, rechargeable energy storage systems, capacitor modules, inverters, interconnects, and venting systems.
- Electric power train means an assembly of electrically connected components which includes, but is not limited to, electric energy storage/conversion systems and propulsion systems.
- Electrical chassis means conductive parts of the vehicle whose electrical potential is taken as reference and which are: (1) conductively linked together, and (2) not high voltage sources during normal vehicle operation.
- Electrical isolation of a high voltage source in the vehicle means the electrical resistance between the high voltage source and any of the vehicle's electrical chassis divided by the working voltage of the high voltage source.
- Electrical protection barrier is the part providing protection against direct contact with high voltage live parts from any direction of access.
- Exposed conductive part is the conductive part that can be touched under the provisions of the IPXXB protection degree and that is not normally energized, but that can become electrically energized under isolation fault conditions. This includes parts under a cover, if the cover can be removed without using tools.
Limits of this page
This page quotes the text of 49 CFR 571.305 as published in the eCFR, current through October 29, 2026. It omits tables, figures, cross-referenced test procedures in other parts, and the preambles and rulemaking history that explain the rule. It does not tell you whether a given vehicle, part or product complies, how to run a test, or what a manufacturer must certify. Compliance questions go to the manufacturer's engineers, qualified counsel or NHTSA. The eCFR is an editorial compilation, not the official legal edition of the Federal Register.
Sources
Sources opened and read November 2, 2026.
- eCFR: 49 CFR 571.305, Standard No. 305; electric-powered vehicles: electrolyte spillage and electrical shock protection; applicable unless a vehicle is certified to § 571.305a. (current through October 29, 2026) (read November 2, 2026)
- eCFR: 49 CFR part 571, Federal Motor Vehicle Safety Standards (current through October 29, 2026) (read November 2, 2026)
Frequently asked questions
What is FMVSS 305?
FMVSS 305 is codified at 49 CFR 571.305, headed "Standard No. 305; electric-powered vehicles: electrolyte spillage and electrical shock protection; applicable unless a vehicle is certified to § 571.305a". Its scope text reads: This standard specifies requirements for limitation of electrolyte spillage and retention of electric energy storage/conversion devices during and after a crash, and protection from harmful electric shock during and after a crash and during normal vehicle operation.
What does FMVSS 305 apply to?
Its application section reads: This standard applies to passenger cars, and to multipurpose passenger vehicles, trucks, and buses with a gross vehicle weight rating (GVWR) of 4,536 kilograms (kg) or less, that use electrical propulsion components with working voltages greater than 60 volts direct current (VDC) or 30 volts alternating current (VAC), and whose speed attainable over a distance of 1.6 km on a paved level surface is more than 40 km/h, that are manufactured before September 1, 2027.
How is FMVSS 305 organized?
The eCFR text has these top-level sections: S1 Scope; S2 Purpose; S3 Application; S4 Definitions; S5 General requirements; S6 Test requirements; S7 Test conditions; S8 Test procedure for on-board electrical isolation monitoring system; S9 Test methods for physical barrier protection from electric shock due to direct and indirect contact with high voltage sources. The finder on this page searches all 47 numbered section headings.
Where does FMVSS 305 define its terms?
In S4 Definitions. This page quotes 12 of the 29 defined terms found there, from the eCFR.
Where are the test conditions and procedures in FMVSS 305?
The headings that cover tests, conditions or procedures include: S6 Test requirements; S6.4 Post-impact test static rollover; S7 Test conditions; S7.2 Vehicle conditions; S7.3 Static rollover test conditions; S7.4 Rear moving barrier impact test conditions. Read the full text in the eCFR for the exact conditions.
Is this page the official text of FMVSS 305?
No. It quotes parts of the eCFR text of 49 CFR 571.305 (current through October 29, 2026, read November 2, 2026) and is an unofficial reference. The eCFR is not the official legal edition of the Federal Register, and the standard changes by rulemaking, so check the current text and NHTSA before relying on it.
Not legal or compliance advice
This page is general information drawn from the sources listed, not legal, engineering or compliance advice, and it is not run by any government agency. Rules, forms and dates change and your agency, base jurisdiction or enforcement officer decides your case, so confirm with the office named on this page before you rely on it. Everything runs in your browser; nothing you enter is sent anywhere.