How the epoxy math works
Floor coatings use the ARCOR rule that one US gallon covers 1604 divided by the thickness in mils, in square feet, at 100% solids. Flood coats and deep pours use volume: area times thickness in cubic inches, divided by 231 cubic inches per US gallon. Volume solids, extra edge or void volume and waste are then applied, and the total is rounded up to whole kits and split by your A:B ratio.
Source: ARCOR Material Coverage sheet (1604 ÷ mils formula, theoretical coverage, 15–20% waste, volume solids).
Maximum pour depth per lift and cure times vary by product and are not assumed here: enter the max lift from your data sheet to split a deep pour. Coverage is theoretical; porous concrete, texture and temperature raise real usage. A coverage figure from the product data sheet overrides the theoretical figure. Ratios are treated as by volume; check whether your product is mixed by weight.
Why one gallon covers so many different areas
Epoxy is sold by volume, but you apply it by thickness, so coverage is just geometry. A US gallon is defined as exactly 231 cubic inches. Spread over a surface at 1 mil (0.001 in) thick, 231 in³ covers 231 ÷ 0.001 = 231,000 in², which is 1,604 sq ft. That is the 1604 constant in the ARCOR coverage sheet: coverage in sq ft per gallon = 1604 ÷ thickness in mils, at 100% solids and with no loss. Double the thickness and the coverage halves.
| Thickness | Sq ft per US gallon (theoretical) |
|---|---|
| 15 mil | 106.9 |
| 20 mil | 80.2 |
| 30 mil | 53.5 |
| 60 mil | 26.7 |
| 1/16 in (62.5 mil) | 25.7 |
| 100 mil (0.1 in) | 16.0 |
| 1/8 in (125 mil) | 12.8 |
That is why a search for “how many square feet does 1 gallon of epoxy cover” gets such different answers. A thin garage-floor coat and a 1/8 in tabletop flood coat differ by a factor of six, and a deep pour is another order of magnitude lower still. The honest answer is always “it depends on thickness”, and this tool makes you choose one.
The three job types
- Floor coating (mils). Gallons = area ÷ (1604 ÷ mils) ÷ volume solids. Use this for primer, build coats and topcoats, running it once per coat.
- Tabletop flood coat. Gallons = area × depth (in cubic inches) ÷ 231 ÷ volume solids. A 1/8 in flood coat is 12.8 sq ft per gallon.
- Deep pour or casting. The same volume formula, applied to the full depth. If your product limits how thick one pour can be, enter that “max lift” from the data sheet and the tool reports how many pours the depth needs.
Whatever the mode, the calculator then adds any extra volume you enter for edges and voids, multiplies by one plus your waste percentage, rounds up to whole kits of the size you enter, and splits the total into Part A and Part B using your mix ratio by volume.
Worked examples
A 20 × 12 ft garage floor at 20 mils. Area = 240 sq ft. Coverage = 1604 ÷ 20 = 80.2 sq ft per gallon, so the base need is 240 ÷ 80.2 = 2.99 gal. With 15% waste that is 3.44 gal, which is 4 one-gallon kits (2 gal of Part A and 2 gal of Part B at 1:1). If your data sheet says 100 sq ft per gallon for the product, type that into the data-sheet coverage box and the tool switches to it.
A 6 × 3 ft tabletop at 1/8 in. Area = 18 sq ft; coverage = 12.8 sq ft per gallon; the volume is 1.40 gal; with 15% waste it is 1.61 gal, so 2 one-gallon kits. If you buy a smaller kit size, enter it and the rounding changes.
A 4 × 2 ft river-table pour, 2 in deep. Area = 8 sq ft, volume = 8 sq ft × 2 in × 144 ÷ 231 = 9.97 gal; with 10% waste, 10.97 gal. With 1.5 gal kits that is 8 kits (12 gal), and at a 2:1 mix that is 8 gal Part A and 4 gal Part B. If the data sheet allows 1/2 in per pour, the depth needs 4 pours.
Volume solids, waste and real-world coverage
Volume solids is the share of the liquid that stays on the surface after any solvent or water leaves. ARCOR's guide uses 100% solids products as the baseline and explains that a product at 75% solids leaves only 75% of each gallon as film, so a lower-solids product needs more liquid for the same thickness. The tool divides the base volume by the solids fraction. If you enter a data-sheet coverage figure, the tool ignores solids because that figure already includes it.
Published coverage is theoretical. ARCOR's sheet itself says to allow 15 to 20% waste for typical applications. Porous or rough concrete soaks up primer, texture and profile add surface area, and cold material is thicker and harder to spread. For these reasons, treat the 15% default as a floor on rough slabs.
Flake and decorative systems
The calculator does not compute broadcast flake or quartz. Those systems apply a base coat, broadcast the media into it, then add one or more topcoats. To estimate the liquid, run floor mode once for the base coat at its mils and again for each topcoat; take the flake or quartz quantity (pounds per square foot) from the supplier's data sheet because it depends on whether you broadcast to rejection or only partially.
Common mistakes
- Confusing mils with inches. 20 mils is 0.020 in; entering 20 in the inch field makes a 20 in pour.
- Forgetting that the mix ratio may be by weight. The tool treats A:B as a ratio by volume. Many products are mixed by weight; follow the data sheet.
- Rounding kits the wrong way. You cannot buy 3.44 gallons if the product comes in 1 gallon kits. The tool rounds up; keep the extra for touch-ups.
- Ignoring pour depth limits. Pouring thicker than a product allows is a cure and heat problem, not a quantity problem. Enter max lift to see the number of pours.
What this calculator does not cover
It does not cover surface preparation, moisture testing, primers, temperature and humidity windows, cure times, or topcoat compatibility. Those come from the product data sheet, which always overrides this estimate. For related quantities use the paint calculator for walls, the concrete calculator for the slab, the flooring calculator for floor area and the wood finish quantity calculator for clear coats on wood.
Frequently asked questions
How many square feet does 1 gallon of epoxy cover?
It depends on thickness. Theoretical coverage is 1604 divided by the thickness in mils, so a 20 mil coat covers about 80 square feet per gallon, a 1/16 inch coat about 26 square feet, and a 1/8 inch flood coat about 13 square feet. Real coverage is lower, so always add waste.
How do I calculate how much epoxy I need for a garage floor?
Multiply length by width, choose the coat thickness in mils, and divide the area by 1604 over mils. For a 20 by 12 foot floor at 20 mils the base volume is about 3 gallons, and with 15 percent waste you would order 4 one-gallon kits.
How much epoxy do I need for a tabletop flood coat?
Use the flood coat mode with the depth in inches. Volume is area times depth in cubic inches divided by 231. A 6 by 3 foot top at 1/8 inch needs about 1.4 gallons, or 1.6 gallons with 15 percent waste.
How do I calculate deep pour epoxy?
Multiply the length, width and depth to get a volume and convert it to gallons by dividing cubic inches by 231. Add extra for voids and waste. Then enter the maximum depth per pour from your data sheet so the calculator tells you how many separate pours the depth needs.
How much waste should I add to an epoxy estimate?
The ARCOR coverage sheet advises 15 to 20 percent waste for typical applications because published coverage is theoretical. Rough or porous concrete, heavy texture and cold material can push real usage higher.
What is volume solids and why does it matter?
Volume solids is the percentage of a liquid that remains as a film after solvents or water evaporate. A 100 percent solids epoxy leaves everything you apply, while a 75 percent solids product leaves three quarters, so it takes more liquid for the same dry thickness. The calculator divides by solids unless you enter a data-sheet coverage figure.
Does this calculate epoxy flake or quartz for a flake floor?
No. It estimates the liquid resin only. Run floor mode once for the base coat and again for each topcoat, and take the flake or quartz quantity per square foot from the system supplier because it depends on how heavily you broadcast.
What is the mix ratio box for?
It splits the total volume between Part A and Part B using the ratio by volume. For a 1 to 1 product, 4 gallons ordered means 2 gallons of each part. If your product is mixed by weight, follow the data sheet instead.
Sources
- ARCOR Material Coverage sheet — coverage in sq ft = 1604 divided by thickness in mils, theoretical coverage with 15 to 20 percent waste, and volume solids (retrieved 2026-10).
- Gallon (Wikipedia) — the US liquid gallon is exactly 231 cubic inches (3.785411784 litres) (retrieved 2026-10).
- Mil (unit) (Wikipedia) — a mil is 0.001 inch (retrieved 2026-10).